Chemical Industrial Sewage Electromagnetic Flow Meter

Model NO.: A+E 81F
Measuring Media: Liquid
Measuring Principle: Electrical Principles
Measurement Object: Closed Pipeline
Certification: ISO
Velocity Range: 0.2~8m/S
Electrode: 316L, Hc, Hb, Ti, Ta
Output: 4-20mA DC, Pulse, RS485
Pressure: Max.16 MPa
Media Temperature: Max 180 C (356 F)
Ambient Temperature: Sensor 80 C(176 F), Converter 50 C(120 F)
Power Supply: 220VAC or 24VDC
Consumption: <8W
Grounding: Made Into The Third Electrode
Trademark: AEAD
Transport Package: Wooden Case, Carboard Box
Origin: Shanghai
HS Code: 90261000
Chemical Industrial Sewage Electromagnetic Flow Meter (A+E 81F)
Chemical Industrial Sewage Electromagnetic Flow Meter

 Highlights

--Large choice of liner materials suitable for drinking water, wastewater, chemicals and other liquids.
--Suitable for use in custody transfer applications.
--Measurement is independent of the flow profile.
--Abrasion and corrosion-resistant liners available.
--Electric conductivity of medium can be used for detection of product change.
--No additional pressure loss.
--No moveable parts and long working life.
--Two-way measurement system to detect the positive and negative flow.
--Site digital LCD displays instantaneous flow, accumulative flow, flow rate. 
--Various types provided according to specific conditions.
--Change the grounding as the third electrode.
 
Applications
--water and sewage treatment
--industrial chemical fluids
--viscous fluids
--slurries
--process flow control
 
Parameters
Item sewage flow meter
Applicable pipe size DN 15-800 (1/2'' to 31-1/2'')
Applicable media liquid with conductivity > 5 uS / cm
Velocity range 0.2~8 m/s (0.66 to 26.2 ft/s)
Accuracy 0.5%FS, 1.0%FS 
Process connection flange, ANSI / GB / JIS, 1.0MPa, 1.6MPa, 4.0MPa, 16MPa optional
Processing temperature -20 to 150°C, according to lining material
Ambient condition -40 to 80°C, relative humidity <95%
Power supply AC220V, 50Hz / DC24V / battery
Display backlight LCD
Operation 4 light touch buttons
Signal output 4-20mA, loading resistance 750Ω,
pulse, 0-3kHz, 5V,
RS485
Consumption <8W
Cable inlet/outlet M20*1.5
Protection transducer IP68, converter IP65
Tube material carbon steel, stainless steel optional
Lining material PTFE, rubber, polyurethane, F46, Fs optional
Electrode material stainless steel, Hastelloy B, Hastelloy C, Titanium, Tantalum, Platinum optional
Grounding made into a third electrode, same material with electrode
Industries chemical, environmental, metallurgical, pharmaceutical, papermaking, water supply and drainage, etc.

 

Main performances of the lining materials

Lining material

Main Performance

Applications

Teflon

1.The most steady material in plastics which is resistible to boiling hydrochloric acid, vitriol fortis as well as strong alkali and organic impregnates.       
2.Not be perfect in abrasion resistance.

Strong corrosive mediums such as strong acid and alkali

F46

1.Have the same abrasion resistance with PTFE.
2.Resistable for low abrasion.
3.Having strong resistance to load pressure.

1.The same as PTFE.
2.Applicable in mediums of low abrasion.

Neoprene

1.Be of good elasticity, retractility and abrasion resistance.
2.Be resistant to low acid, alkali and salt but not for oxidation mediums.

Water, sewage and slurry, mineral serosity of low abrasion.

Polyurethane

1.Be of good abrasion resistibility.
2.Not be perfect in acid/alkali resistance.
3.Can't be used for water mixed with organic impregnants.

Applicable in mineral serosity, slurry and coal slurry of high abrasion.

 

Main performances of the electrode materials

Electrode material  

Applications

Stainless steel SS316

Applicable in water, sewage and corrosive mediums. Widely used in industries of petrol, chemistry, carbamide, etc.

Hastelloy B(HB)

Having strong resistance to hydrochloric acid of any consistence which is below boiling point. Also resistible against vitriol, phosphate, hydrofluoricacid,organic acid etc which are oxidable acid, alkali and non-oxidable salt.

Hastelloy C(HC)

Be resistant to oxidable acid such as nitric acid, mixed acid as well as oxidable salt such as Fe+++,Cu++and sea water

Titanium

Applicable in seawater, and kinds of chloride, hypochlorite salt, oxidable acid (including fuming nitric acid), organic acid, alkali etc. Not resistant to a pure reducing acid(such as sulphuric acid, hydrochloric acid)corrosion. But if acid contains antioxidant(such as Fe+++,Cu++) is greatly reduce corrosion.

Tantalum

Having strong resistance to corrosive mediums that is similar with glass. Almost applicable in all chemical mediums. Except for hydrofluoric acid, oleum and alkali.

Platinum-iridium

Almost be applicable in all chemical mediums except for aqua fortis, ammonium salt.

 


If you are interested in chemical industrial sewage flow meter, please call our office at +86-(0)21-5869 6328.
Alternatively, you can send us an email or use the contact form which can be found on the contact page of our website.

 HL-ring chain centrifugal Bucket Elevator main characteristics:

1.         smooth operation, high transmission efficiency.

2.         Multi-hopper form, should be preferred.

3.         Strong adaptability, easy installation and maintenance, long life.

4.         The whole small size, high speed, to ensure rapid and uniform delivery.

Bucket Elevator oil factory


      Bucket Elevator peanut

 

Bucket Elevator soybean   

    Bucket Elevator corn

Bucket Elevator

Oil Seeds Bucket Elevator,Chain Bucket Elevator,Auto Plant Oil Seeds Bucket Elevator,Ring Chain Bucket Elevator

Dingzhou Yongsheng Grain & Oil Machinery Co.,Ltd. , http://www.oilpresschina.com