600kvar Inductive Load Bank for Generator Testing

Model NO.: AC415/400-600KVAR
HS Code: 9030339000
Model NO.: AC415/400-600KVAR
HS Code: 9030339000
Kaixiang Load Bank scientific and technology level is in leading position in this industry, besides general functions, it has following unique advantages:
High Power Load: high load power density, large capacity of single set, parallel running to finish super power testing, and realize tens of megawatts of power loading.
Accurate Data: with high precision data collection module and measuring meter, related equipment has passed the certification by CMA (China Metrology Accreditation) qualification testing institution, and ensures the reliability of data.
Flexible Control Mode: based on different using habit, several control modes as following can be choose, local panel operation, remote box controlling, and intelligent software.  
Intelligent Loading: after setting generator rated power in software, system realize rapid loading through preset proportion, automatically and continuously load multiple power value and common tests, like stepping, full load, and over load, so that improve working efficiency.   High Efficiency Data Management: display real-time testing data, generate curves graphs automatically, also can put data into storage. According to generator set No. set up testing file, support to query at any time, and improve data management efficiency.
Comprehensive Protection Function: multiple protection, like over temperature, smoke. When in danger, automatically terminate the test and give alarm to protect safety of personnel and equipment.
Stable Running: with the latest generation control module as the core, a sharp rise in system response speed and anti-interference performance, avoid function failure in complex electrical environment, and ensure system running stably and reliably.  
New Load Bank Technology: using the international advanced AC load bank technology, overcome the old water bank defects, such as bear bumpy, unable to use when go to sea, realize Mooring Trial and Sea Trail, and simulate the real working condition of generator running.   
Mature Manufacturing Technology: load element using excellent anti-corrosion materials; waterproof insulation container packaging, suitable for adverse environment such as ocean. Internal layout is reasonable, air channel is clear, rapid heat emission, and satisfy continuous working need.
Technical Parameter
System Parameter
Rating voltage/frequency 415V/400V, 3 phase 4 wire 50Hz
Max Load Power Inductive Load: 600KVAR
Load Resolution Total 645KVAR @415V 3 phase 4wire,50HZ
1KVAR,2 KVAR, 2KVAR, 5KVAR,5KVAR, 10KVAR, 10KVAR, 20KVAR, 20KVAR,20KVAR, 50KVAR, 100KVAR,200KVAR,200KVAR  
Total 600KVAR @ 400V 3phase 4wire, 50HZ
0.93KVAR,1.86KVAR, 1.86KVAR, 4.65KVAR, 4.65KVAR,9.3KVAR, 9.3KVAR, 18.6KVAR, 18.6KVAR,18.6KVAR,46.5KVAR, 93KVAR,186KVAR,186KVAR  
 
Load Tolerance (each step) ±5%
Load Tolerance (overall) ±3%
Fan &Control Voltage External AC 3 phase 4 line, 415V/50Hz  
Wire Connection Load bank input--Copper bar (star coupling "Y")
Control power input--Connector-bar
Communication Interface RS485,RS232
Insulation F
Max Protection Grade IP21
Duty Cycle Continuous  
Cooling Forced air cooling, by Axial Fan; horizontal inlet air, horizontal air outlet
Transportation Hoisting, there are lifting lug in top of casing
Color Grey RAL7035 or as required
Operating Environment Parameter
Workplace  Indoor or outdoor with canopy  
Ambient Temperature -10ºC~+50ºC
Relative Humidity ≤95%
Atmospheric Pressure 86~106kPa
Brands of Main Components
Contactor   Schneider
Fuse  Miro
PLC  Siemens
Alloy Resistor   Kaixiang
Data Processing Software  Kaixiang

600kvar Inductive Load Bank for Generator Testing
600kvar Inductive Load Bank for Generator Testing
600kvar Inductive Load Bank for Generator Testing
600kvar Inductive Load Bank for Generator Testing
600kvar Inductive Load Bank for Generator Testing
600kvar Inductive Load Bank for Generator Testing
  Kaixiang Load Bank scientific and technology level is in leading position in this industry, besides general functions, it has following unique advantages:
High Power Load: high load power density, large capacity of single set, parallel running to finish super power testing, and realize tens of megawatts of power loading.
Accurate Data: with high precision data collection module and measuring meter, related equipment has passed the certification by CMA (China Metrology Accreditation) qualification testing institution, and ensures the reliability of data.
Flexible Control Mode: based on different using habit, several control modes as following can be choose, local panel operation, remote box controlling, and intelligent software.  
Intelligent Loading: after setting generator rated power in software, system realize rapid loading through preset proportion, automatically and continuously load multiple power value and common tests, like stepping, full load, and over load, so that improve working efficiency.   High Efficiency Data Management: display real-time testing data, generate curves graphs automatically, also can put data into storage. According to generator set No. set up testing file, support to query at any time, and improve data management efficiency.
Comprehensive Protection Function: multiple protection, like over temperature, smoke. When in danger, automatically terminate the test and give alarm to protect safety of personnel and equipment.
Stable Running: with the latest generation control module as the core, a sharp rise in system response speed and anti-interference performance, avoid function failure in complex electrical environment, and ensure system running stably and reliably.  
New Load Bank Technology: using the international advanced AC load bank technology, overcome the old water bank defects, such as bear bumpy, unable to use when go to sea, realize Mooring Trial and Sea Trail, and simulate the real working condition of generator running.   
Mature Manufacturing Technology: load element using excellent anti-corrosion materials; waterproof insulation container packaging, suitable for adverse environment such as ocean. Internal layout is reasonable, air channel is clear, rapid heat emission, and satisfy continuous working need.
Technical Parameter
System Parameter
Rating voltage/frequency 415V/400V, 3 phase 4 wire 50Hz
Max Load Power Inductive Load: 600KVAR
Load Resolution Total 645KVAR @415V 3 phase 4wire,50HZ
1KVAR,2 KVAR, 2KVAR, 5KVAR,5KVAR, 10KVAR, 10KVAR, 20KVAR, 20KVAR,20KVAR, 50KVAR, 100KVAR,200KVAR,200KVAR  
Total 600KVAR @ 400V 3phase 4wire, 50HZ
0.93KVAR,1.86KVAR, 1.86KVAR, 4.65KVAR, 4.65KVAR,9.3KVAR, 9.3KVAR, 18.6KVAR, 18.6KVAR,18.6KVAR,46.5KVAR, 93KVAR,186KVAR,186KVAR  
 
Load Tolerance (each step) ±5%
Load Tolerance (overall) ±3%
Fan &Control Voltage External AC 3 phase 4 line, 415V/50Hz  
Wire Connection Load bank input--Copper bar (star coupling "Y")
Control power input--Connector-bar
Communication Interface RS485,RS232
Insulation F
Max Protection Grade IP21
Duty Cycle Continuous  
Cooling Forced air cooling, by Axial Fan; horizontal inlet air, horizontal air outlet
Transportation Hoisting, there are lifting lug in top of casing
Color Grey RAL7035 or as required
Operating Environment Parameter
Workplace  Indoor or outdoor with canopy  
Ambient Temperature -10ºC~+50ºC
Relative Humidity ≤95%
Atmospheric Pressure 86~106kPa
Brands of Main Components
Contactor   Schneider
Fuse  Miro
PLC  Siemens
Alloy Resistor   Kaixiang
Data Processing Software  Kaixiang

600kvar Inductive Load Bank for Generator Testing
600kvar Inductive Load Bank for Generator Testing
600kvar Inductive Load Bank for Generator Testing
600kvar Inductive Load Bank for Generator Testing
600kvar Inductive Load Bank for Generator Testing
600kvar Inductive Load Bank for Generator Testing
 

Direct-actuated Valve

Actuated Valve,Direct Acting Valve,Electric Actuated Valve,Hydraulic Actuated Valve

A1BEST International Corporation , https://www.aone-best.com