Sizing a Load Bank 10.5kv 1760kw High Voltage Generator Testing

Model NO.: Sizing a load bank 10.5KV 1760KW
Voltage: AC10.5kv
Frequency: 50Hz
Rated Power: 1760kw
Insulation Grade: F Class
Protection Grade: IP54
Trademark: Triumph Load
Transport Package: Container
Specification: 6058mm*2438mm*2591mm (L* W* H)
Origin: Hebei, China
HS Code: 903033900
Sizing a load bank 10.5kv 1760kw High Voltage Generator Testing 
1.Product Introduction
AC10.5KV 1760KW High Voltage AC Generator Testing Load Bank
High voltage load bank,the optional voltage range is 6.6KV~35KV,can be directly used for large high voltage
generator,
need not to be equipped with conventional step-down transformer.We can also provide regular load bank for high voltage 
equipment,need to use step-down transformer together.
2.AC10.5KV-1760KW High Voltage AC Generator Testing Load Bank Application
Large generator system testing in ocean engineering, drilling facilities,ship construction etc field 
Factory testing for generator, static voltage characteristic test, speed characteristic test;
Marine generator overload protection test,parallel operation test,reverse power and reverse current protection 
test
Assist shipyard in mooring test,sea trial test
Assist with the acceptance of the vessel generator test
Eliminate the carbon deposition of generator
As the generator loading system
Periodic running test for standby generator 
UPS inspection and maintenance
Ship battery charging/discharging system testing
The acceptance of new system and testing of servicing equipment
3.AC10.5KV-1760KW High Voltage AC Generator Testing Load Bank Working Environment
Altitute:≤2500m
Temperature:-10°C~50°C
Humidity:≤95%RH
Working Mode:Continuous work(>6hours continuous long-term work per day)
4. AC10.5KV-1760KW High Voltage AC Generator Testing Load Bank Technical  Specifications

Load a single set of system parameters

Rated voltage 
and frequency

AC 3 phase 3 wire, 10.5KV/50Hz

Maximum load power

Apparent Power: 1760KW

Load Resolution

400KW,400KW,400KW,400KW,160KW

Power Factor

1

Load accuracy (per file)

± 5%

Load accuracy (whole)

± 3%

Display accuracy

0.5

Control Power

External AC 3 phase 4 wire, 380V/50Hz

Wire Connection 

Load bank input--Copper bar (star coupling "Y")
Control power input--Connector-bar

Wiring port design

Allow sufficient space to ensure that users can easily access the load cables.
External load penetrating openings in the cables after the cables have sufficient 
waterproof capability, and sufficient mechanical strength.

Communication Interface

RS485, RS232

And machine methods

Computer software and machine

Insulation class

Class F

Protection class

IP54 

Noise

3 m away from the outlet is less than 9 0 db

Way of Working

Continuous working

Cooling

Forced air cooling, horizontal inlet air, vertical exhaust cooling

Chassis construction

Container package, with up to the top of the ladder, with inlet and outlet 
grilles and door protection

Enclosure

Container type,with a ladder, air inlet and outlet with mesh enclosure and protection door

Transportation

Hoisting, there are lifting lug in top of casing

Chassis Size

Approximately 6058mm × 2438 mm × 2591mm (L × W × H)

Weight

Approximately 6000kg

Work environment parameters

Workplace

Coastal areas, outdoor work

Operating Temperature

- 25 ºC ~ + 6 0 ºC (lower limit of the instrument's temperature-10 ºC)

Relative Humidity

≤ 95%

Altitude

≤ 2500m

Atmospheric pressure

86 ~ 106kPa
Sizing a Load Bank 10.5kv 1760kw High Voltage Generator Testing
Sizing a Load Bank 10.5kv 1760kw High Voltage Generator Testing
Sizing a Load Bank 10.5kv 1760kw High Voltage Generator Testing


5.Why choosing us

The earliest and most professional manufacturer of AC/DC Load Bank in China, dedicated to this industry for more than 20 years.
The most patent technology and scientific research awards gainer in China.
Advanced detection method and strict inspection procedure build the qualified quality.
Customized production meet the individual requirement.
Prompt delivery & excellent after sales service.
Cooperate with many well-known enterprise, offer OEM and ODM service to world famous brands.
Certified with China Classification Society (CCS) and ISO9001:2008 Quality Certificate.
Triumph Load is the first brand in the emergency power supply test & maintenance industry in China.
6.Contact Information
Sizing a Load Bank 10.5kv 1760kw High Voltage Generator Testing


 

Coil Straightener Feeder with compact design are preferred to be used in case of only small available space as well as in case of less delicate coil material with big material square. They normally are used at middle-sized feeding lengths and middle-sized number of press strokes per minute.

Coil Straightener Feederare composed of a Decoiler Straightener unit and Nc Servo Feeder unit and are particular suitable for profiling, Metal Stamping Press line, roll forming line, laser cutting, shear and many other machining processes.


By combination of straightener and roll feed into one machine, so called feeder-straightener, which is positioned directly at the press, the needed space for a (very often long) material loop of straightened material can be saved..
 
The feeder-straightener is supplied with material out of a (in comparison) very small loop of not straightened material below the Decoiler .

Coil Straightener Feeder is suitable for automotive industry, automobile stamping, appliances manufacturing, computer and electronic components, hardware and metal parts/Metal Fabrication/Precision Metal Stamping industry etc industry. Such as Bracket, Damper, brake Pad, Tie Bar, Electric Accessory, Shell Parts Of Printers, Computer Frame,Slide Rail of Car Seat, Splash Shield of car body and etc. 


Coil Straightener Feeder

Press Room Automation, Coil Straightener Feeder,NC Leveler Feeder, Unwinding Leveling Feeding

Mayflay Machinery(huizhou) Co.,LTD , https://www.pressfeeders.com