Precession Vortex Gas Flowmeter Head Faults and Solutions

Precession Vortex Gas Flow Meter Head Faults and Solutions:

The intelligent precession vortex gas flowmeter adopts the latest micro-processing technology and has the advantages of strong function, wide flow range, simple operation and maintenance, and easy installation and use. The main technical indicators have reached the advanced level of similar foreign products. Widely used in petroleum, chemical, electric power, metallurgy, coal and other industries measuring various gases. What is the reason and solution for screwing in the head of the swirl gas meter ?

First, precession swirl meter head shows instantaneous flow, normal pressure, temperature display does not match the temperature of the work site

1. Temperature indicates "-75C" or exceeds "100°C".

The temperature sensor is damaged. Replaceable sensor.

2. The temperature indication is above or below the actual temperature of the site. After the sensor is replaced, this phenomenon still remains.

The temperature and pressure circuit is damaged. Replaceable temperature and pressure circuit.

Second, the precession vortex flowmeter head no display

1. The flow meter does not have 24V power supply or battery power. Supply 24V power to the flowmeter or replace the flowmeter battery.
2. The flow meter panel is damaged. Replace the flow meter LCD panel.
3. The flowmeter board is damaged. Replace the flow meter board.
4. The power supply is connected incorrectly or disconnected. Find and reconnect.

Third, precession swirl gas flow meter head temperature, instantaneous flow is displayed, the pressure does not match the actual working pressure indicator

1. If the pressure indication is “80” or the flowmeter “upper pressure limit” (the upper limit can be found in the flow meter selection reference table).

One is to connect a new pressure sensor to see if the meter shows the local atmospheric pressure. If the local atmospheric pressure is displayed, the original sensor is damaged. Replaceable pressure sensor. The second is the external half of the new pressure sensor. If the meter still shows “80”, it proves that the flowmeter motherboard is bad. Replaceable flow meter board.

2. The pressure indication is basically a certain value (the field working pressure changes greatly, the flowmeter meter shows no change in pressure or changes).

One is that pressure sensors take pressure holes. Can clear the pressure hole. The second is that the linear calibration curve of the pressure sensor deteriorates. The pressure sensor can be replaced or recalibrated.

Four, precession vortex flow meter head shows normal temperature and pressure, no instantaneous flow rate display

1. The size of the flow meter is too large. If the type is too large, the flow meter will show no flow. One is to lower the lower cutoff frequency of the flowmeter (this allows the flowmeter to be used, but it will cause the flowmeter to be less accurate). The second is to replace the small size flowmeter.
2. The preamplifier has no current input. The flowmeter has no power supply and is used for 24V external power supply or battery power supply.
3. The preamplifier has no frequency output. Replaceable preamplifier.
4. The primary swirling vortex meter plate is damaged. Replaceable flow meter board.

Extended reading: Ming Yu controlled flow meter

Leisuwash 360 Glow

Leisuwash specializing in manufacture Automatic Car Wash Machine, Touchless Car Wash , Automatic Touchless Car Wash, touchless car wash equipment, robot car wash, smart car wash system, leisuwash 360, leisuwash leibao 360, laserwash 360, leisuwash touchless car wash machine, leisu wash touchless car wash automatic, leisu wash 360 high pressure touchless car wash equipment, robo car wash, touch free car wash, leisuwash 360 touch free car wash, leisuwash 360 price, automatic car wash price, leisuwash in malaysia, no touch automatic car wash machine.

Leisuwash 360 touchless car wash machine high intelligent high quality, with car wash + car care + drying process totally, each car wash takes time 1 minute to 5 minutes which depends on the car wash mode.

Leisuwash 360 car wash automatic touchless is distinguished by the use of new, more advanced American technology of Automatic Car Wash. The 3D technology of washing is based on the use of a special bent-shaped manipulator with 360 rotations. Rotating around the car, the manipulator reads data about its contours and adjusts itself to the optimum distance for washing.