Transformer Loss of Life

Oil-filled transformers utilized in transmission and distribution systems are robust units designed for extended operational lifespans. These transformers are engineered to consistently operate under full load conditions and can endure temporary surges in load significantly above their rated capacity. A key factor influencing transformer longevity is the degradation of cellulose insulation. The aging process of insulation is influenced by time, temperature, moisture levels, and oxygen content, with temperature being the most critical variable. High-quality oils and effective oil preservation systems play a crucial role in mitigating the detrimental effects of moisture and oxygen on insulation. Historically, many older transformers have operated for decades at loads far below their nameplate ratings. However, several contemporary trends are contributing to transformers running hotter than in the past. Global warming has led to rising ambient temperatures in various regions, and new applications such as server farms and electric vehicle charging stations are driving up overall energy demands. As a result, utility companies are increasingly operating transformers at higher loading levels to maximize asset utilization. Within power and distribution transformers, internal temperatures are not uniform. The section of the winding experiencing the highest temperature typically undergoes the most significant insulation degradation. The hot-spot temperature, which refers to the hottest point within the transformer, is determined by the manufacturer and included in the transformer's test report. In 1995, the IEEE revised its guide for loading mineral-oil-immersed transformers (C57.91), introducing a thermal method for assessing insulation life. This method calculates a relative aging rate and percentage of life remaining based on the hot-spot temperature over time. The aging rate is standardized to 1 at a hot-spot temperature of 110°C, corresponding to a transformer operating at an ambient temperature of 30°C with an average winding temperature rise of 65°C and an additional 15°C rise above the average winding temperature. Even minor temperature fluctuations can dramatically affect insulation life. According to extensive testing and modeling, the normal expected lifespan of a new transformer operating continuously at 110°C is approximately 180,000 hours (around 20.55 years). Operating at 98°C (12°C below the standard) extends this lifespan to 627,000 hours (3.5 times longer), while operating at 122°C (12°C above the standard) reduces it to just 55,000 hours (70% shorter). For most distribution transformers, daily and weekly load patterns vary significantly. Periods of operation above 110°C are often balanced out by longer durations below this threshold. For instance, a typical daily cycle might include low loads overnight and peak loads for several hours in the afternoon. From an aging perspective, 12 hours at 92°C, 8 hours at 105°C, and 4 hours at 125°C equates to 24 hours of continuous operation at 110°C. Therefore, accurately monitoring the hot-spot temperature is essential for determining aging rates and estimating remaining operational life. Minimizing peak transformer temperatures is vital for prolonging equipment life. The Weschler Transformer Advantage stands out as an excellent solution for both temperature monitoring and cooling control. Certain Advantage models equipped with the calculated winding method can also track aging and remaining life. During the initial setup of the Advantage, users input the hot-spot temperature rise from the transformer’s test report. Additionally, the expected transformer lifespan is entered, along with any prior usage if applicable. The system then monitors the time-temperature profile to calculate the aging rate (in hours per hour) and cumulative aging (in total hours). Remaining operational hours are also displayed. This data is accessible via the front panel, communication port, and the accompanying Advantage Monitor app. The Monitor app integrates the IEEE aging equation into a Loss of Insulation Life Calculator, allowing users to predict aging rates and consumed hours for specific temperature and duration scenarios. **Weschler Transformer Advantage** While alternative approaches like measuring changes in winding resistance are being explored, the temperature-based method outlined here remains well-defined and standardized through IEEE C57.91. When implemented in the Weschler Transformer Advantage, it provides a user-friendly tool for utilities to effectively monitor and manage critical transformer assets. --- **Need Assistance?** Reach out to Weschler for support.

Impact Roller

Impact Roller,Impact Roller Compactor,Deep Impact Roller,Belt Conveyor Impact Roller

NINGBO TANSUO MACHINE MANUFACTURING CO., LTD. , https://www.tsjxidler.com