Transformer Loss of Life

Oil-filled transformers utilized in transmission and distribution networks are robust devices engineered for extended service lives. These transformers are designed to operate continuously under full load conditions and can handle temporary overloads at significantly higher capacities. A key element influencing transformer longevity is the degradation of the cellulose insulation. The aging process of insulation is influenced by time, temperature, moisture levels, and oxygen content, with temperature being the most significant factor. High-quality oils and effective oil preservation systems play a crucial role in minimizing deterioration caused by moisture and oxygen. Historically, older transformers often operated below their nameplate ratings for decades. However, several contemporary factors are causing transformers to operate at elevated temperatures compared to the past. Rising ambient temperatures in various regions worldwide, coupled with increased electricity demands from server farms and electric vehicle charging stations, are contributing to this trend. Additionally, utility companies aim to optimize asset utilization by running transformers at higher loads. Power and distribution transformers do not maintain uniform internal temperatures. The area within the winding experiencing the highest temperature generally sees the most significant insulation wear. The so-called “hot spot” temperature, determined by the manufacturer and included in the transformer's test report, is a critical metric. The 1995 revision of the IEEE Guide for Loading Mineral-Oil-Immersed Transformers (C57.91) introduced a thermal method for assessing insulation life. This method calculates the relative aging rate and life expectancy based on the hot spot temperature recorded over time. The aging rate is standardized at a hot spot temperature of 110°C, which corresponds to a transformer operating at 30°C ambient temperature with an average winding rise of 65°C and a hot spot rise over the average winding temperature of 15°C. Even minor fluctuations in temperature can drastically affect insulation life. According to extensive testing and modeling, a new transformer’s expected lifespan under continuous operation at 110°C is approximately 180,000 hours (around 20.55 years). Operating at 98°C (12°C below the standard) extends the expected life to 627,000 hours (3.5 times longer). Conversely, operating at 122°C (12°C above the standard) reduces the expected life to just 55,000 hours (a 70% reduction). For most distribution transformers, loading varies throughout the day and week. Periods of operation above 110°C are often balanced by longer periods below this threshold. For example, a typical daily cycle might involve a low load at night followed by a high load for several hours in the afternoon. From an aging perspective, 12 hours at 92°C, 8 hours at 105°C, and 4 hours at 125°C equates to 24 hours at 110°C. Continuously monitoring the hot spot temperature is essential for accurately calculating aging and estimating remaining life. Minimizing peak transformer temperatures is vital for extending the equipment's operational life. The Weschler Transformer Advantage is an excellent solution for both temperature monitoring and cooling management. Certain Advantage models, using the calculated winding method, can also track aging and remaining life. During the initial setup of the Advantage, the hot spot temperature rise from the transformer test report is entered. The expected transformer life is also input at this stage, allowing the system to account for any prior usage if applicable. The Advantage then monitors the time-temperature profile to calculate the aging rate (hours per hour) and cumulative aging (total hours). It also provides the remaining operational hours. This information is accessible via the front panel, communication port, and the accompanying Advantage Monitor app. The Monitor app integrates the IEEE aging equation into a Loss of Insulation Life Calculator, enabling users to predict aging rates and consumed hours for specific temperature and duration scenarios. **Weschler Transformer Advantage** While alternative methods to estimate transformer aging, such as monitoring changes in winding resistance, are being explored, the temperature-based approach outlined here is well-established and standardized through IEEE C57.91. As implemented in the Weschler Transformer Advantage, it serves as a user-friendly tool for utilities to monitor and manage their critical transformer assets effectively. --- **Need Help?** Contact Weschler for assistance with your transformer monitoring needs.

Rollers

Conveyor Roller,Steel Pipe Carrying Idler Rollers,Steel Idler Rollers,Electric Rollers

NINGBO TANSUO MACHINE MANUFACTURING CO., LTD. , https://www.tsjxidler.com